Power Supplies
|
|
|
PLR-3006 |
 |
|
|
|
Features
|
- AC/DC 300W PS/2 Type 4U Hot Swap Redundant Power Supply with
multiple output support Pentium 4 and AMD Athlon CPU and storage
- Input Voltage Range: 90 ~ 132V / 180 ~ 264V with selector
- Output Voltage: 5V / 3.3V / 12V / -5V /-12V / 5VSB
- Over voltage and short circuit protection
- Safety Standard: UL/CB/TUV/CE
- EMI Standards:FCC Class B / VDE
- Aluminum case for excellent power dissipation
|
|
Specifications
|
| INPUT |
Voltage Rating |
90 ~ 132V / 180 ~ 264V |
| Input Current (115/230VAC) |
8A / 4A |
| Frequency |
47Hz~63Hz |
| In-rush Current |
60A max./230V (at cold start) |
| OUTPUT |
DC
Voltage |
Ripple & Noise |
Total
Reg. |
Output Current Rating
MIN / MAX |
| 3.3V |
50mV |
±4% |
0.5A / 15A |
| +5V |
50mV |
±5% |
2.5A / 35A |
| +12V |
120mV |
±5% |
0.5A / 15A |
| -5V |
50mV |
±10% |
0A / 0.5A |
| -12V |
120mV |
±10% |
0A / 0.8A |
| +5Vsb |
50mV |
±5% |
0A / 1.5A |
| +3.3V & +5V Power |
175W |
| Total Output Power |
300W |
| Hold up time |
16ms min. at 110V AC full load |
| Over Power
Protection |
105%~160% of max load |
| Over Voltage
Protection |
+5V: 5.8V~6.9V
+3.3V: 3.8V~4.3V |
| Efficiency |
72% min. at full load |
| Cooling |
Air convection by +12V DC
fan |
| Operation Temperature |
0șC~50șC |
| Storage Temperature |
-40șC ~70șC |
| Humidity |
Operating: to 85% relative humidity, non-condensing
at 25ºC
Storage: to 95% relative humidity, non-condensing at 50ºC |
| MTBF |
>100K hours |
| EMC |
EN61000 -4-2/-3-4-5, CE Approval, FCC class
B, CIS PR 22 Class B |
| Safety |
UL, CS A, TUV, NAMCO, CB |
| Dimension |
175 (D)x 150 (W)x 84(H) mm |
|
|
|